Envíos a todo Mexico Catálogo Civic Sun · Precios en MXN · Compra protegida Asesoría solar especializada
Civic Sun Engineer
VICTRON ENERGY BMV-712 Smart
Battery monitors

BMV-712 Smart

SKU principal: BAM030712000

BMV-712 Smart

<p>With Bluetooth built-in,
the BMV Smart is ready for the Internet of Things (IoT) era. With Bluetooth being implemented in most other Victron Energy products,
wireless communication between products will simplify system installation and enhance performance.</p><p>To read more about the full BMV range & accessories,
see this <a href="https://www.victronenergy.com/blog/2019/08/27/battery-monitors-and-monitoring-solutions/">blog</a>. </p>

Códigos SKU

BAM030712000 BAM030712000R BAM030712200 BAM030712200R
DATOS DEL FABRICANTE

Especificaciones técnicas

Supply Voltage Range
[ 6.5, 70 ] VDC
Current Rating
500 A
Battery Capacity Measurement Range
[ 1, 9, 999 ] Ah
Current Draw
1 mA
Input Voltage Measurement Range Auxiliary Battery
[ 6.5, 70 ] VDC
Operating Temperature Range
[ -40, 50 ] °C
Aux Input Fo Auxiliary Battery Voltage
1
Temperature Sensor
Optional (ASS000100000)
Temperature Measurement Range
[ -20, 50 ] °C
Communication Port
VE.Direct
Bluetooth
1
Programmable Relay
Bistable relay 60V / 1A , normally open (function can be inverted)
Display
1
Visual Alarm On Device
1
Audible Alarm On Device
1
Current Measurement Resolution
0.01 A
Voltage Measurement Resolution
0.01 V
Capacity Measurement Resolution
0.1 Ah
State Of Charge Measurement Resolution
0.1 %
Time To Go Measurement Resolution
1 min
Temperature Resolution
1 °C
Measurement Accuracy
0.4 %
Current Measurement Accuracy
0.4 %
Voltage Measurement Accuracy
0.3 %
Positive Cable
1.5m cable with 1A fuse
Aux Cable
1.5m cable with 1A fuse
Shunt Connection Terminals
M10 bolts
Display Shunt Cable
10 metre 6-core UTP with RJ12 connectors
Colour
Black
Protection Category
IP55 (not for outdoor use)
Installation
Flush mount
Front Diameter
63 mm
Front Bezel
69 x 69mm
Body Diameter
52 mm
Body Depth
31 mm
Shunt
500A / 50mV
Safety
EN 60335-1
Emisison Immunity
EN 55014-1, EN 55014-2
Automotive Directive
ECE R10-4, EN 50498
Data Stored
Battery voltage, Battery current, Battery temperature, Battery state of charge percentage, Battery midpoint deviation, Starter battery voltage
Data Retention Period
46 d
Supply Voltage Range
[ 6.5, 70 ] VDC
Current Rating
500 A
Battery Capacity Measurement Range
[ 1, 9, 999 ] Ah
Current Draw
1 mA
Input Voltage Measurement Range Auxiliary Battery
[ 6.5, 70 ] VDC
Operating Temperature Range
[ -40, 50 ] °C
Aux Input Fo Auxiliary Battery Voltage
1
Temperature Sensor
Optional (ASS000100000)
Temperature Measurement Range
[ -20, 50 ] °C
Communication Port
VE.Direct
Bluetooth
1
Programmable Relay
Bistable relay 60V / 1A , normally open (function can be inverted)
Display
1
Visual Alarm On Device
1
Audible Alarm On Device
1
Current Measurement Resolution
0.01 A
Voltage Measurement Resolution
0.01 V
Capacity Measurement Resolution
0.1 Ah
State Of Charge Measurement Resolution
0.1 %
Time To Go Measurement Resolution
1 min
Temperature Resolution
1 °C
Measurement Accuracy
0.4 %
Current Measurement Accuracy
0.4 %
Voltage Measurement Accuracy
0.3 %
Positive Cable
1.5m cable with 1A fuse
Aux Cable
1.5m cable with 1A fuse
Shunt Connection Terminals
M10 bolts
Colour
Grey
Protection Category
IP55 (not for outdoor use)
Front Diameter
63 mm
Front Bezel
69 x 69mm
Body Diameter
52 mm
Body Depth
31 mm
Shunt
500A / 50mV
Safety
EN 60335-1
Emisison Immunity
EN 55014-1, EN 55014-2
Automotive Directive
ECE R10-4, EN 50498
Data Stored
Battery voltage, Battery current, Battery temperature, Battery state of charge percentage, Battery midpoint deviation, Starter battery voltage, Load output Current
Data Retention Period
46 d
Supply Voltage Range
[ 6.5, 70 ] VDC
Current Rating
500 A
Battery Capacity Measurement Range
[ 1, 9, 999 ] Ah
Current Draw
1 mA
Input Voltage Measurement Range Auxiliary Battery
[ 6.5, 70 ] VDC
Operating Temperature Range
[ -40, 50 ] °C
Aux Input Fo Auxiliary Battery Voltage
1
Temperature Sensor
Optional (ASS000100000)
Temperature Measurement Range
[ -20, 50 ] °C
Bluetooth
1
Programmable Relay
Bistable relay 60V / 1A , normally open (function can be inverted)
Display
1
Visual Alarm On Device
1
Audible Alarm On Device
1
Current Measurement Resolution
0.01 A
Voltage Measurement Resolution
0.01 V
Capacity Measurement Resolution
0.1 Ah
State Of Charge Measurement Resolution
0.1 %
Time To Go Measurement Resolution
1 min
Temperature Resolution
1 °C
Measurement Accuracy
0.4 %
Current Measurement Accuracy
0.4 %
Voltage Measurement Accuracy
0.3 %
Positive Cable
1.5m cable with 1A fuse
Aux Cable
1.5m cable with 1A fuse
Shunt Connection Terminals
M10 bolts
Display Shunt Cable
10 metre 6-core UTP with RJ12 connectors
Colour
Black
Protection Category
IP55 (not for outdoor use)
Installation
Flush mount
Front Diameter
63 mm
Front Bezel
69 x 69mm
Body Diameter
52 mm
Body Depth
31 mm
Shunt
500A / 50mV
Safety
EN 60335-1
Emisison Immunity
EN 55014-1, EN 55014-2
Automotive Directive
ECE R10-4, EN 50498
Data Stored
Battery voltage, Battery current, Battery temperature, Battery state of charge percentage, Battery midpoint deviation, Starter battery voltage
Data Retention Period
46 d
Supply Voltage Range
[ 6.5, 70 ] VDC
Current Rating
500 A
Battery Capacity Measurement Range
[ 1, 9, 999 ] Ah
Current Draw
1 mA
Input Voltage Measurement Range Auxiliary Battery
[ 6.5, 70 ] VDC
Operating Temperature Range
[ -40, 50 ] °C
Aux Input Fo Auxiliary Battery Voltage
1
Temperature Sensor
Optional (ASS000100000)
Temperature Measurement Range
[ -20, 50 ] °C
Communication Port
VE.Direct
Bluetooth
1
Programmable Relay
Bistable relay 60V / 1A , normally open (function can be inverted)
Display
1
Visual Alarm On Device
1
Audible Alarm On Device
1
Current Measurement Resolution
0.01 A
Voltage Measurement Resolution
0.01 V
Capacity Measurement Resolution
0.1 Ah
State Of Charge Measurement Resolution
0.1 %
Time To Go Measurement Resolution
1 min
Temperature Resolution
1 °C
Measurement Accuracy
0.4 %
Current Measurement Accuracy
0.4 %
Voltage Measurement Accuracy
0.3 %
Positive Cable
1.5m cable with 1A fuse
Aux Cable
1.5m cable with 1A fuse
Shunt Connection Terminals
M10 bolts
Display Shunt Cable
10 metre 6-core UTP with RJ12 connectors
Colour
Grey
Protection Category
IP55 (not for outdoor use)
Installation
Flush mount
Front Diameter
63 mm
Front Bezel
69 x 69mm
Body Diameter
52 mm
Body Depth
31 mm
Shunt
500A / 50mV
Safety
EN 60335-1
Emisison Immunity
EN 55014-1, EN 55014-2
Automotive Directive
ECE R10-4, EN 50498
Data Stored
Battery voltage, Battery current, Battery temperature, Battery state of charge percentage, Battery midpoint deviation, Starter battery voltage
Data Retention Period
46 d