- D C Input Operating Voltage Range
- [
8,
70
] V
- Current Consumption Rem On
- 2.2 mA
- Current Consumption Low Cell
- 1.2 mA
- Current Consumption Rem Off
- 1.2 mA
- Load Disconnect Output
- Normally high (Vbat – 0.1V)
- Load Disconnect Output Source
- 1 A
- Charge Disconnect Output
- Normally high (Vbat –0.6V)
- Charge Disconnect Output Source
- 10 mA
- Pre Alarm Output
- Normally free floating - In case of alarm: output voltage Vbat -0.1 V
- Pre Alarm Current Rating
- 1 A
- Remote Terminals
- Remote L and Remote H
Use modes:
1. ON when the L and H terminal are interconnected
2. ON when the L terminal is pulled to battery minus (V <3.5 V)
3. ON when the H terminal is high (2.9 V <VH <Vbat)
4. OFF in all other conditions
- Operating Temp Range
- [
-20,
50
] °C
- Max Humidity
- 95 %
- Battery Communication Terminals
- Terminals with M8 circular connectors
- Input Output Terminals
- Screw terminals
- Power Supply Cable
- Recommended fuse size 0.3 A - 2.5 (dependent on devices connected to Load disconnect and pre-alarm output)
- Material
- ABS
- Colour
- Matt black with a blue sticker
- Protection Category
- IP20
- Weight
- 0.1 kg
- Height
- 106 mm
- Width
- 42 mm
- Depth
- 23 mm
- Safety
- EN 60950
- Emission
- EN 55014-1,
EN-IEC 61000-6-3
- Immunity
- EN 55014-2,
EN-IEC 61000-6-1,
EN-IEC 61000-6-2
- Automotive
- ECE R10-4