Envíos a todo Mexico Catálogo Civic Sun · Precios en MXN · Compra protegida Asesoría solar especializada
Civic Sun Engineer
VICTRON ENERGY Smart BatteryProtect
Battery Protect

Smart BatteryProtect

SKU principal: BPR065022000

Smart BatteryProtect

<p>The Smart BatteryProtect disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine. </p><p>When using Bluetooth to program the Smart BatteryProtect any required engage/disengage levels can be set. <br>Alternatively,
one of nine predefined engage/disengage levels can be set with the programming pin (see manual). </p><p>If required,
Bluetooth can be disabled.</p> <p class="MsoNormal">The Smart BatteryProtect is a uni-directional device. It can only deal with current in one direction,
so either current to a load,
or current from a charger,
but not both currents at the same time. In addition to this,
current only can only flow from the IN terminal to the OUT terminal. In case of use with a load,
the battery connects to the IN terminal,
and in case of use with a charger,
the charger connects to the IN terminal.<br></p>

Códigos SKU

BPR065022000 BPR110022000 BPR110048000 BPR122022000
DATOS DEL FABRICANTE

Especificaciones técnicas

Battery Voltage Nominal
12V or 24V (automatic detection)
Operating Voltage Range
[ 6, 35 ] V
Maximum Continuous Load Current Rating40
65 A
Maximum Continuous Load Current Rating60
39 A
Peak Current Rating
250 A
Reverse Current
No
Current Consumption When On B O
1.2 mA
Current Consumption When On B
1.4 mA
Current Consumption When Off B O
0.7 mA
Current Consumption When Off B
0.9 mA
Alarm Output Delay
12 s
Maximum Load Alarm Output
50 mA
Load Disconnect Delay
90 s
Load Reconnect Delay
30 s
Default Threshold Disengage12
10.5 V
Default Threshold Disengage24
21 V
Default Threshold Engage12
12 V
Default Threshold Engage24
24 V
Remote On Off Terminal
1
Bluetooth
Yes
Protections
Output short-circuit
Operating Temperature Range
[ -40, 50 ] °C
Battery And Load Terminals
M6 bolts
Remote Terminal
Screw terminal two pole
Alarm Terminal
Screw terminal 3-pole
Protection Category Connection Area
IP00
Protection Category Electronic Components
IP67
Weight
0.2 kg
Height
48 mm
Width
55 mm
Depth
106 mm
Battery Voltage Nominal
12V or 24V (automatic detection)
Operating Voltage Range
[ 6, 35 ] V
Maximum Continuous Load Current Rating40
100 A
Maximum Continuous Load Current Rating60
60 A
Peak Current Rating
600 A
Reverse Current
No
Current Consumption When On B O
1.2
Current Consumption When On B
1.4 mA
Current Consumption When Off B O
0.7
Current Consumption When Off B
0.9 mA
Alarm Output Delay
12 s
Maximum Load Alarm Output
50 mA
Load Disconnect Delay
90 s
Load Reconnect Delay
30 s
Default Threshold Disengage12
10.5 V
Default Threshold Disengage24
21 V
Default Threshold Engage12
12 V
Default Threshold Engage24
24 V
Remote On Off Terminal
1
Bluetooth
Yes
Protections
Short-circuit proof
Operating Temperature Range
[ -40, 50 ] °C
Battery And Load Terminals
M8 bolts
Remote Terminal
Screw terminal two pole
Alarm Terminal
Screw terminal 3-pole
Protection Category Connection Area
IP67
Protection Category Electronic Components
IP00
Weight
0.5 kg
Height
61 mm
Width
41 mm
Depth
164 mm
Battery Voltage Nominal
12V or 24V (automatic detection)
Operating Voltage Range
[ 6, 35 ] V
Maximum Continuous Load Current Rating40
220 A
Maximum Continuous Load Current Rating60
132 A
Peak Current Rating
600 A
Reverse Current
No
Current Consumption When On B O
1.2 mA
Current Consumption When On B
1.4 mA
Current Consumption When Off B O
0.7 mA
Current Consumption When Off B
0.9 mA
Alarm Output Delay
12 s
Maximum Load Alarm Output
50 mA
Load Disconnect Delay
90 s
Load Reconnect Delay
30 s
Default Threshold Disengage12
10.5 V
Default Threshold Disengage24
21 V
Default Threshold Engage12
12 V
Default Threshold Engage24
24 V
Remote On Off Terminal
1
Bluetooth
Yes
Protections
Output short-circuit
Operating Temperature Range
[ -40, 50 ] °C
Battery And Load Terminals
M8 bolts
Remote Terminal
Screw terminal two pole
Alarm Terminal
Screw terminal 3-pole
Protection Category Connection Area
IP00
Protection Category Electronic Components
IP67
Weight
0.8 kg
Height
60 mm
Width
123 mm
Depth
121 mm
Battery Voltage Nominal
48V
Operating Voltage Range
[ 44, 64 ] V
Maximum Continuous Load Current Rating40
100 A
Maximum Continuous Load Current Rating60
60 A
Peak Current Rating
600 A
Reverse Current
No
Current Consumption When On B O
1.2 mA
Current Consumption When On B
1.4 mA
Current Consumption When Off B O
0.7 mA
Current Consumption When Off B
0.9 mA
Alarm Output Delay
12 s
Maximum Load Alarm Output
50 mA
Load Disconnect Delay
90 s
Load Reconnect Delay
30 s
Default Threshold Disengage12
10.5 V
Default Threshold Disengage24
21 V
Default Threshold Engage12
12 V
Default Threshold Engage24
24 V
Remote On Off Terminal
1
Bluetooth
Yes
Protections
Output short-circuit
Operating Temperature Range
[ -40, 50 ] °C
Battery And Load Terminals
M8 bolts
Remote Terminal
Screw terminal two pole
Alarm Terminal
Screw terminal 3-pole
Protection Category Connection Area
IP00
Protection Category Electronic Components
IP67
Weight
0.5 kg
Height
61 mm
Width
41 mm
Depth
164 mm